6 MAINTENANCE

0558 012 633

- 25 -

© ESAB AB 2015

NOTE!

It is NOT RECOMMENDED to use the CV switch setting when using a CC power

source. Extreme wire feed speed sensitivity exists that makes it difficult to set a

stable welding condition. The arc stability is very dependent on maintaining

constant "Tip To Work" (TTW) distance which is almost impossible to control

when welding manually. CV setting is only recommended for use with CV power

sources.

Typical welding voltages for 5000 Aluminum are between 21 and 25 volts, which

limits the wire feed speed of the MobileFeed, especially if trying to weld with 035”

diameter 5356 alloy. Welding with wire diameters ≤3/64” and/or below 22 arc

volts could cause problems with limited wire feed speed and the inability to

achieve a good welding condition.

NOTE!

On many CV power sources, the actual welding arc voltage is less than the

“Open Circuit Voltage” (OCV) set on the power source front panel. Therefore, an

extra 3 to 6 volts may be added to the power source front panel setting to achieve

the actual arc voltage needed or shown in the tables.

5.3.6

Shutdown

1. Release the torch trigger switch to break the arc.

2. When leaving the equipment unattended, always turn off and disconnect all power to the

equipment and turn off the shielding gas supply at the source.

6

MAINTENANCE

WARNING!

Make sure that the branch circuit or main disconnect switch is OFF or electrical

input circuit fuses are removed from the power source main supply before

attempting any inspection or work on the inside of the wire feeder. Placing the

power switch on the welding machine in the OFF position does not remove all

power from inside of the equipment.

WARNING!

Inspection, troubleshooting, and repair of this equipment should be undertaken

by a competent individual having at least general experience in the maintenance

and repair of semi-conductor electronic equipment. Maintenance or repair should

not be undertaken by anyone without such qualifications.

6.1

Inspection and service

Keep equipment in clean and safe operating condition, free of oil, grease, liquid, and metallic

particles which can cause short circuits.

Regularly check cylinder valves, regulators, hoses, and gas connections for leaks with a

soap solution.

Check for and tighten loose hardware including electrical connections. Loose power

connections overheat during welding.

Immediately replace all worn or damaged power cables and connectors. Check for frayed

and cracked insulation, particularly in areas where conductors enter equipment.



1   ...   13   14   15   16   17   18   19   20   ...   80

Similar:

Valid for: serial no. WxxK530xxxx MobileFeed 301 avs iconValid for: serial no. WxxK530xxxx mobileFeed 201 avs
English us
Valid for: serial no. WxxK530xxxx MobileFeed 301 avs iconS Titelseite
Avs constituye el tema principal de esta edición. A la introducción del avs, para
Valid for: serial no. WxxK530xxxx MobileFeed 301 avs icon3-5.pdf [formulario avs ticino]

Valid for: serial no. WxxK530xxxx MobileFeed 301 avs icon02_Observaciones_periodo_de_consulta_publica.pdf [formulario avs 111]

Valid for: serial no. WxxK530xxxx MobileFeed 301 avs icon129951702.pdf [formulario avs indipendente]

Valid for: serial no. WxxK530xxxx MobileFeed 301 avs iconel-municipio-1893-01-31.pdf [formulario avs indipendente]

Valid for: serial no. WxxK530xxxx MobileFeed 301 avs iconForm 19 2002 with osha 301 info
Center, Raleigh, nc 27699-1235 within two years of the date of your injury or last payment of medical compensation. For occupational...
Valid for: serial no. WxxK530xxxx MobileFeed 301 avs iconMicrosoft Word sb0109 Spanish
Under the Paperwork Reduction Act of 1995, no persons are required to respond to a collection of information unless it contains a...
Valid for: serial no. WxxK530xxxx MobileFeed 301 avs iconCorte constitucional
Referencia: expedientes t 301. 339, t 302. 178, t 307. 205 y t 307. 744 (acumulados)
Valid for: serial no. WxxK530xxxx MobileFeed 301 avs iconDecisions CoP12 and valid after CoP12
Cooperación con la Organización de las Naciones Unidas para la Agricultura y la Alimentación (fao) 2


Descargar 12.23 Kb.
Ver original pdf